Diagnosis - Sherlock 2000
A patented diagnostics system for determining the causes of malfunctions in any A/C system through analysis of pressures and temperatures.
Key Features
- TYPES OF REFRIGERANT R134a and R12
- TYPES OF SYSTEMS
- Traditional
- Flooded
- Continual cut-in flooded
- 2 MINUTES for results.
- DIAGNOSIS PRINTOUT complete with data, graphs, and solution for the problem.
- EXAMPLES OF DIAGNOSIS
- No refrigerant in system
- Defroster pressure switch
- Clogged intake line
- Refrigerant low
- Capillary valve
- Clogged condenser or hose.
- Air flow to evaporator
- System OK
- Excess refrigerant
- Incorrect condenser airflow
- Air in system
- Check mixing door
- High and low pressures inverted
- Pulley does not engage
- Replace compressor
- SOFTWARE UPDATES via Internet, RS232 serial port.
Ways of Use
- Sherlock 2000 Clima tester
- Sherlock PC - Pc Interface with the special “Sherlock PC” program. Data and diagnosis report with color graphs and print option.
Technical Specifications
| Refrigerant types | R12 e R134a |
| Voltage | 12V (automobile battery) |
| Hoses | 1,5 meters |
| Instrument dimensions | 350 x 160 x 120 mm |
| Instrument weight | 1,5 kg |
| Case dimensions | 480 x 370 x 180 mm |
| Full case weight | 3 kg |
Available Versions
XS100.000000