ECK 2500-N8

Fully automatic single-gas station for recovering, recycling, and recharging R134 refrigerant, compliant with SAE J-2788 standard.

Automatic Functions

Automatic Functions

Standard Features

  • LEAK TEST: automatic during the vacuum phase.
  • ONBOARD BOTTLE FILLING: automatic.
  • AUTOMATIC DISCHARGE of non-condensable gases from the bottle.
  • SERVICE ALARM: acoustic and visual, for maintenance and filter replacement request.
  • USB PORT for software updates.
  • REFRIGERANT MANAGEMENT: for creating a customized archive of all refrigerant transactions.
  • OPERATOR CODE: for assigning an operator password to protect against unauthorized use of the station.
  • DISTRIBUTOR GROUP: built-in, patented unit optimized for top performance and dependability.
  • DATABASE ADVANCED: integrated database allowing the user to enter new vehicle models.
  • FLUSHING SOFTWARE for automatic flushing of series A/C systems. For use with AEK102-N7.

Options

  • HYBRID :
    Special function for hybrid vehicles (Factory option).
  • SANIFLUX (SANI+):
    the first sanitizing system integrated in an A/C charging station (green station body with this option).
    SANIFLUX (SANI+)
  • FLUSHING KIT (AEK102-N7):
    for flushing the A/C system with refrigerant. External
    bottle and metal adapters included.
    FLUSHING KIT (AEK102-N7)
  • A/C DIAGNOSIS MODULE (DIAKIT):
    integrated, for all types of A/C systems, featuring printout of diagnosis and problem solution.
    A/C DIAGNOSIS MODULE (DIAKIT)
  • AUTOMATIC TRACER KIT (UVKIT-7)
    featuring collapsible cartridges.
    AUTOMATIC TRACER KIT (UVKIT-7)
  • NITROGEN BOTTLE CONNECTOR (N2)
    (bottle not included): the station automatically charges the A/C system with nitrogen and checks for leaks, monitoring pressure drops and giving a leak alarm.
    NITROGEN BOTTLE CONNECTOR (N2)
  • STATIC DIAGNOSIS KIT (KITSTA001.00)
    for diagnosing A/C systems.
    STATIC DIAGNOSIS KIT (KITSTA001.00)

Technical Specifications

Type of refrigerant R134a
Service procedure Fully automatic or manual
Voltage 220-240V 50/60 Hz
Scale resolution 10 g
Oil scale resolution 5 g
Working temperature range 11/49°C
Filter system 2 filters for humidity
Vacuum pump 115 liter/min capacity, 0.1 mbar vacuum level
Sealed compressor 12 cc, high pressure
Recovery speed 300 g/min in liquid phase
Refrigerant bottle 22 litres, refillable
Hoses 3 metres
Overall size 55 x 60 x 105 cm
Weight 90 Kg
Thermal printer Standard equipment
Pressure gauges Class 1
Display LCD
Bottle temperature sensor Integrated
Bottle heater Automatic

Available Versions

XK670A000000 VERSIONE STANDARD